Call 07942537926 70% Response Rate
Send Enquiry
Product Brochure
Capacity | 10KVA |
Brand | EELTEC |
Battery Type | Static state + manual maintenance bypass |
Waveform | Sine wave |
Crest Factor | 3:01:00 AM |
Short Circuit Current | Short current for 0.1s (200% current) |
Output Frequency Stability | + / - 0.05% |
Model Number | IP 10K |
Total Harmonic Distortion | 3% (linear load) |
Noise at 1 M | less than 60 dB |
Input Voltage Range | +/-20% |
Degree of Protection | IP20 |
Power | 8KW |
Running Temperature | 0-40 Degree C |
Altitude | 1000m output nominal power (with increase of 100m, it will reduce output of 1%) max 4000m |
Transient Response | +/-5%, 10ms |
Input Frequency | 45 - 65Hz |
Power Factor | 0.8 |
Output Range of Phase Lock | Without synchronization: + /- 2% (settable +/-1% on the control panel) |
Overload Capacity | 110% /125% /150% rated current 300 min/ 10min /1min |
Output Frequency | 50 / 60 Hz |
Input Rectifier | 3 phase 6 pulses |
Input Phase | 3 phase 4 wire and ground |
Battery Max Charge Current | 30A |
Relative Humidity | Less than 95% (without condensing) |
Phase Voltage Setting | 200 - 244VAC (control panel ) |
Applicable Standards | EN50091-1-EMC EN50091-2liv.A |
Rated Voltage | 380/400/415V optional |
Country of Origin | Made in India |
View Complete details
Product Brochure
Brand | EELTEC |
Capacity | 30KVA |
Input Phase | 3 - Phase |
Battery Type | Static state + manual maintenance bypass |
Waveform | Sine Wave |
Overload Capacity | 110% /125% /150% rated current 300 min/ 10min /1min |
Crest Factor | 3:01:00 AM |
Running Temperature | 0-40 Degree C |
Input Frequency | 45 - 65Hz |
Power Factor | 0.8 |
Transient Response | +/-5%,10ms (Output) |
Altitude | 1000m output nominal power (with increase of 100m,it will reduce output of 1%) max 4000m |
Input Voltage Range | +/-20% |
Output Rated voltage | 380/400/415V optional |
Bypass Transfer Time | Inverter / bypass transfer switch time(Overload): 0ms inverter / bypass transfer switch time (fault |
Input Rectifier | 3 phase 6 pulses |
Applicable Standards | EN50091-1-EMC EN50091-2liv.A |
Bypass Input Voltage Range | 15% - 25% (the front control panel selectable) |
Degree of Protection | IP20 |
Relative Humidity | Less than 95% (without condensing) |
Model Number | IP 30K |
Power | 24KW |
Output Range of Phase Lock | Without synchronization: + /- 2% (settable +/-1% on the control panel) |
Total Harmonic Distortion | 3% ( linear load) |
Max Charge Current | 30A |
Noise At 1 M | less than 60 dB |
Output Frequency Stability | + / - 0.05% |
Short Circuit Current | Short current for 0.1s (200% current) |
Country of Origin | Made in India |
View Complete details