Mohali, Punjab
GST No. 03ABNPD2036R1ZK
Call 07942537926 74% Response Rate
Product Brochure
Brand | EELTEC |
Capacity | 20 KVA |
Input Phase | 3 - Phase |
Configuration | 3 Phase IN - 3 Phase OUT |
Waveform | Sine Wave |
Crest Factor | 3:1 |
Country of Origin | Made in India |
Output Rated Voltage | 380V / 400V / 415V (As per the Customers Demand) |
Protection Degree | IP20 |
Product Series | Induss Power Series |
Power Factor | 0.9 |
Input Frequency | 50Hz |
Running Temperature | 0-40 Degree C |
Power | 16 kW |
Applicable Standards | EN50091-1-EMC EN50091-2liv.A |
Model Number | IP 20K |
Input Voltage Range | 380V-460V |
View Complete details
Product Brochure
Brand | EELTEC |
Capacity | 200 KVA |
Battery Type | Static state + manual maintenance bypass |
Waveform | Sine wave |
Crest Factor | 3:01:00 AM |
Country of Origin | Made in India |
Model Number | IP 200K |
Power | 160KW |
Power Factor | 0.8 |
Input Phase | 3 phase 4 wire and ground |
Input Voltage Range | +/-20% |
Input Frequency | 45 - 65Hz |
Input Rectifier | 3 phase 6 pulses |
Output Rated Voltage | 380/400/415V optional |
Output Phase Voltage Setting | 200 - 244VAC (control panel ) |
Output Transient Response | +/-5%,10ms |
Output Frequency Stability | + / - 0.05% |
Output Range of Phase Lock | Without synchronization: + /- 2% (settable +/-1% on the control panel) |
Total Harmonic Distortion | 3% ( linear load) |
Short Circuit Current | Short current for 0.1s (200% current) |
Output Overload Capacity | 110% /125% /150% rated current 300 min/ 10min /1min |
Max Charge Current | 30A |
Running Temperature | 0-40 Degree C |
Relative Humidity | Less than 95% (without condensing) |
Altitude | 1000m output nominal power (with increase of 100m,it will reduce output of 1%) max 4000m |
Noise At 1 M | less than 60 dB |
Degree of Protection | IP20 |
Applicable Standards | EN50091-1-EMC EN50091-2liv.A |
Product Series | Induss Power Series |
View Complete details
Product Brochure
Brand | EELTEC |
Capacity | 30KVA |
Input Phase | 3 - Phase |
Battery Type | Static state + manual maintenance bypass |
Waveform | Sine Wave |
Overload Capacity | 110% /125% /150% rated current 300 min/ 10min /1min |
Crest Factor | 3:01:00 AM |
Country of Origin | Made in India |
Model Number | IP 30K |
Power | 24KW |
Power Factor | 0.8 |
Input Voltage Range | +/-20% |
Input Frequency | 45 - 65Hz |
Input Rectifier | 3 phase 6 pulses |
Output Rated voltage | 380/400/415V optional |
Transient Response | +/-5%,10ms (Output) |
Output Frequency Stability | + / - 0.05% |
Output Range of Phase Lock | Without synchronization: + /- 2% (settable +/-1% on the control panel) |
Total Harmonic Distortion | 3% ( linear load) |
Short Circuit Current | Short current for 0.1s (200% current) |
Max Charge Current | 30A |
Bypass Input Voltage Range | 15% - 25% (the front control panel selectable) |
Bypass Transfer Time | Inverter / bypass transfer switch time(Overload): 0ms inverter / bypass transfer switch time (fault |
Running Temperature | 0-40 Degree C |
Relative Humidity | Less than 95% (without condensing) |
Noise At 1 M | less than 60 dB |
Altitude | 1000m output nominal power (with increase of 100m,it will reduce output of 1%) max 4000m |
Degree of Protection | IP20 |
Applicable Standards | EN50091-1-EMC EN50091-2liv.A |
View Complete details